BGSDR - E-57 EMULSIFIER

  • MSDS: BGSDR
  • Manufacturer: MET L CHEK COMPANY
  • Product Name: E-57 EMULSIFIER
  • National Stock Number: 6850-01-268-6711
Product Identification

Product ID:E-57 EMULSIFIER
MSDS Date:01/01/1997
FSC:6850
NIIN:01-268-6711
MSDS Number: BGSDR

Responsible Party
MET-L-CHEK COMPANY
1639 EUCLID ST
SANTA MONICA, CA 90404-3770
US

Emergency Phone: 310-450-1111

Info Phone: 310-450-1111

Cage: 98733

Contractor
MET-L-CHEK COMPANY
00000 SANTA MONICA, CA 90404 US

Telephone: 310-450-1111/FAX 310452-4046

Cage: 98733

Ingredients

MINERAL OIL, PETROLEUM DISTILLATE OR PETROLEUM HYDROCARBON

CAS: 64741-96-4

RTECS: PY8040000

OSHA PEL 5 MG/M3 AS OIL MIST

ACGIH TLV: 5 MG/M3 AS OIL MIST

Hazards

LD50 LC50 Mixture:TLV FOR OIL MIST IS 5 MG/M3.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN, RESPIRATORY
AND GASTROINTESTINAL TRACTS (HMIS). ACUTE - EYE CONTACT PRESUMED
NON-IRRITATING. SKIN CONTACT SLIGHT IRRITATING. INHALATION OF
VAPORS AT ELEVATED TEMPERATURES OR MIST MAY CAUSE MILD IRRITATION
OF UPPERRESPIRATORY TRACT. INGESTION MAY RESULT IN VOMITING.
ASPIRATION MUST BE AVOIDED. CHRONIC - UNKNOWN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN CONTACT- IRRITATION, INGESTION - POSSIBLE
VOMITING.
Medical Cond Aggravated by Exposure:PRE-EXISTING SKIN AND RESPIRATORY
DISORDERS MAY BE AGGRAVATED BY EXPOSURE.

First Aid

First Aid:EYE CONTACT - FLUSH WITH WATER. SKIN CONTACT - FLUSH WITH
WATER, THEN WASH WITH SOAP AND WATER. INHALATION - REMOVE TO FRESH
AIR. PROVIDE OXYGEN IF BREATHING IS DIFFICULT. INGESTION -DO NOT
INDUCE VO MITING. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>93.3C, 200.F
Extinguishing Media:WATER FOG, FOAM, DRY CHEMICAL, CARBON DIOXIDE. DO
NOT USE DIRECT STREAM OF WATER.
Fire Fighting Procedures:MATERIAL WILL NOT BURN UNLESS PREHEATED. DO
NOT ENTER CONFINED FIRE SPACE WITHOUT FULL BUNKER GEAR, INCLUDING
A POSITIVE PRESSURE NIOSH-APPROVED SELF-CONTAINED BREATHING
APPARATUS.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:SOAK UP WITH ABSORBENT SUCH AS CLAY, SAND OR
OTHER SUITABLE MATERIAL. DISPOSE OF IAW LOCAL, STATE AND FEDERAL
REGULATIONS FOR OIL RESIDUE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL PLACE AWAY FROM HEAT,
FLAMES AND OXIDIZING MATERIALS.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:IF EXPOSURE EXCEEDS TLV, USE NIOSH-APPROVED
RESPIRATOR TO PREVENT OVEREXPOSURE
Ventilation:USE MECHANICAL VENTILATION OR LOCAL EXHAUST TO MAINTAIN
EXPOSURE BELOW TLV(S).
Protective Gloves:CHEMICAL RESISTANT TO MINIMIZE SKIN CONTACT.
Eye Protection:NO SPECIAL PROTECTION REQUIRED.
Other Protective Equipment:AS REQUIRED TO MINIMIZE SKIN CONTACT.
Work Hygienic Practices:MINIMIZE SKIN CONTACT. WASH WITH SOAP AND
WATER BEFORE EATING, DRINKING, OR SMOKING, OR USING TOILET.
Supplemental Safety and Health

Chemical Properties

HCC:V5
Boiling Pt:=204.4C, 400.F
Spec Gravity:0.92(H20=1)
Solubility in Water:EMULSIFIABLE
Appearance and Odor:PINK OILY LIQUID, SLIGHT HYDROCARBON ODOR

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS.
Stability Condition to Avoid:HEAT, OPEN FLAMES AND CONTACT WITH
OXIDIZING MATERIALS.
Hazardous Decomposition Products:CAN PRODUCE CARBON MONOXIDE AND OTHER
UNIDENTIFIED ORGANIC COMPOUNDS
Conditions to Avoid Polymerization:HEAT, OPEN FLAMES AND OXIDIZING
MATERIALS.

Disposal

Waste Disposal Methods:PLACE IN APPROPRIATE DISPOSAL FACILITY IN
COMPLIANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Regulatory

SARA Title III Information:NONE
State Regulatory Information:CALIFORNIA PROPOSITION 65
NOTICE-DETECTABLE AMOUNTS OF SOME CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE BIRTH DEFECTS, OR OTHER REPRODUCTIVE HARM MAY
BE FOUND IN VARIOUS PRODUCTS YOU PURCHASE FROM MET-L-CHEK, IN
THEIR VAPORS OR MAYRESULT FROM THEIR USE. READ AND FOLLOW LABEL
DIRECTIONS AND INFORMATION GIVEN ON MATERIAL SAFETY DATA SHEETS,
AND USE CARE WHEN HANDLING OR USING ALL NON-DEST RUCTIVE TEST
CHEMICAL PRODUCTS. FOR FURTHER INFORMATION, CONTACT THE MET-L-CHEK
COMPANY, 1639 EUCLI D STREET, SANTA MONICA , CA 90404.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.